REQUIREMENTS:

In situ machining of heat exchanger division plate slot, which was corroded and required welding and re-machining to original specification.

SOLUTION:

Mirage supplied a standard 2 axis MR2200.

The machine was fixed to the heat exchanger using a two bolt mounting system, allowing both fast mounting and fast alignment.

The machine was then levelled and aligned from the face and the division plate re-machined.

Time savings are large as in most cases the exchanger can be left in place or bought into a work shop with the tubes left in place..

OUTCOME:

Machined division slots back to original specification.